The project
This Coquitlam home had no existing ductwork — the original heating was electric baseboard throughout. The homeowners wanted to upgrade to a heat pump for both heating and cooling without the cost and disruption of installing a full duct system. Grove Mechanical designed a 5-zone Mitsubishi ductless system: one outdoor multi-zone unit connected to five indoor wall-mount heads, one in each main living area and bedroom. Each zone has independent temperature control, and the system provides both heating and cooling year-round.
With no existing ductwork or chases, routing refrigerant line sets to five separate rooms required careful planning to minimize visible runs. Grove Mechanical ran lines through the attic where possible and used matching line set covers on exterior walls for a clean finish.
Sizing a multi-zone system requires matching the outdoor unit capacity to the combined load of all indoor heads, while ensuring no single zone is oversized or undersized. Grove Mechanical performed a full Manual J heat load calculation for each room before selecting equipment.
A 5-zone Mitsubishi system requires a dedicated 240V circuit with adequate ampacity. The existing panel had capacity, but the dedicated circuit needed to be run from the panel to the outdoor unit location — a 40-foot run through the crawlspace.
The homeowners reduced their monthly heating bill from an average of $380 (electric baseboard) to $140 (heat pump) — a 63% reduction. They also have central air conditioning for the first time, with individual temperature control in every room. The Kumo Cloud app lets them set schedules and adjust temperatures remotely. The project qualified for a $6,000 CleanBC rebate for switching from electric resistance heating.
A ductless heat pump can be a path to consider when a qualified review confirms the home, equipment, and installation scope are suitable. Current program eligibility and any operating-cost outcome depend on the home, equipment, use, energy rates, and provider terms.
A good rule of thumb is one indoor head per main living area and one per bedroom — similar to this project. However, the right number depends on your home's layout, insulation, and how you use the space. Grove Mechanical performs a full heat load calculation and zone analysis before recommending a system size.
Line sets are run through walls and attic spaces wherever possible. Where exterior runs are unavoidable, Grove Mechanical uses matching line set covers (also called line hide) that are painted to match the home's exterior. The result is a clean, professional finish.
Multi-Zone Outdoor Unit
MitsubishiMXZ-5C42NAHZ2
5-zone, 42,000 BTU, Hyper-Heat, rated to -30°C
Wall-Mount Indoor Heads (×5)
MitsubishiMSZ-FS Series
9,000–12,000 BTU each, WiFi enabled, i-see sensor, sleep mode
Kumo Cloud WiFi Interface
MitsubishiApp-based control for all 5 zones from a single interface
Line Set Installation
Grove MechanicalRefrigerant line sets run through walls and attic — concealed where possible
2 project photos from this documented installation
4 installed equipment and scope details
3 on-site challenges explained
Completed in Coquitlam, BC